The iGS-221 integrated controller is the simplest and most complete solution for integrated climate management and CO2 enrichment or venting. Simultaneously controls the temperature, humidity and CO2 concentration. The iGS-221 prioritizes actions according to a logical sequence, avoiding contradictory actions. Intelligently manages simultaneously 6 actions: CO2 enrichment, venting, humidifying, dehumidifying, heating and cooling. Ready to use, just adjust your set points!

  • Description

    Control module
    Multiple operation modes are available to ensure effective control. The controller will automatically adjust its operating differential to keep conditions closest to temperature, relative humidity and CO2 concentration set points. The controller database allows you to know the real conditions of your garden over the last 24 hours.
    • Displays climatic conditions, CO2 concentration, advices, alarms and errors
    • Photocell to enable day/night set points

    Connection Module
    Connected to a compatible alarm system (0.6 A @ 120 Vac or 2A @ 30 Vdc), the connection module will activate alarms to notify a temperature or a humidity control problem. The three IGS-25 power boxes, each controlling your equipment with 2 auxiliary outputs, can be connected (Ethernet or RG45 cable) on different circuits up to 50 feet off the connection module.
    • Three IGS-25 power boxes (6 auxiliary outputs)
    • Dry contacts for temperature and/or humidity alarms
    CO2 Control
    The iGS-221 controls CO2 enrichment equipment or the ventilation for intake of fresh air containing CO2. It can operate the intake-exhaust fan(s) cyclically to replenish the garden's atmosphere in oxygen as needed for the plants and for CO2 combustion generator. The air sampling is optimized by means of an integrated fan and the internal CO2 sensor reads values from 0 to 5000 ppm.
    • Precise CO2 electronic sensor: ± 75 ppm
    • Adjustable set points for day and night from 0 à 4900 ppm
    Temperature and Relative Humidity Control
    The controller intelligently manages 4 actions: heating, cooling (AC or fan), humidifying, dehumidifying. It allows adjustment of 5 set points per climate parameter: set points for day, night, temperature and humidity's differential, alarm and event logging.
    • Temperature precise sensor: ±1.8°F (±1°C)
    • Adjustable separate set points for day and night
    • Relative humidity precise sensor: ±3.5% RH
    Temperature and Relative Humidity Control
    • Adjusting the hourly cyclic ventilation from 0 to 30 minutes.
    • Setting the ventilation (fan) to start in case of abnormally high relative humidity.
    • Setting the ventilation (fan) to start in case of abnormally high temperature.
    • Controlling temperature and humidity in a cold climate using the ventilation instead of an air conditioner and a dehumidifier.
    Capacity
    The iGS-221 feeds up to 45 amps of controlled equipment (need 3 separate circuits 110-120 V). Equipment which uses other voltage then 110-120 V, like large capacity air conditioning unit, may be controlled by using an iGS-DCS. You can also increase the capacity with a load switcher box iLS4-121, iLS4-121s or iLS4-241.
    • 120 V, 15 A, 2 HP load capacity (1 circuit)
    • 120 V, 45 A, 6 HP load capacity (3 circuits)
    • 120 V, 30 A, 4 HP load capacity (2 circuits)

  • Specifications
    Controller Functions
    Integrated Controller Yes
    Digital Display Yes
    Info, Error or Alarm Messages Yes
    Day/Night Detection Photocell
    Day and Nigth Setpoints Yes
    Adjustable Operation Priority No
    Intelligent Self Management Equipment Yes
    Performance Analysis Temperature, RH and CO2 Control
    Self Audit of Controller Errors Yes
    Data LogLast 24 hours
    Contact for External Alarms Temperature, RH and CO2
    Integrated Fan for Air Sampling Magnetic levitation sleeve bearing, 7 cfm
    Auxiliary Devices Control
    Controlled Actions Heating and Cooling, and Humidifying and Dehumidifying, and Increase and Decrease CO2 concentration
    Controlled Auxiliary Outputs 3 x iGS-25 (6 auxiliary outlets)
    Simultaneously Controlled Equipment 6 (2 for temperature, 2 for RH and 2 for CO2 )
    Temperature Control
    Temperature Display Yes
    Temperature Sensor Accuracy ±1.8°F (±1°C)
    Temperature Sensor Range -4 °F to +122 (-20 °C to +50 °C)
    Adjustable Temperature Setpoint Yes
    Temperature Differential Fixed or dynamic
    Adjustable Temperature Differential Yes
    Controlled Equipment for Temperature Heater or Air Conditionner or Fans
    Humidity Control
    RH Display Yes
    Sensor accuracy ± 3,5 % RH
    RH Sensor Range 0 to 100 % RH
    Adjustable RH Setpoint Yes
    RH Differential Fixed or dynamic
    Adjustable RH Differential Yes
    Controlled Equipment for RH Humidifier or Dehumidifier or Fans
    CO2 Control
    RH Display Yes
    CO2 Concentration Display Yes
    CO2 Power Indicator Yes
    Dangerous CO2 Concentration Alert Yes
    CO2 Sensor Accuracy ± 75 ppm
    CO2 Sensor Range 0 to 5000 ppm
    Adjustable CO2 Concentration Setpoint 400 to 4900 ppm
    CO2 Concentration Differential Fixed or dynamic
    Adjustable CO2 Concentration Differential Yes
    Altitude Correction Yes
    Controlled Equipment for CO2 CO2 tank or gas burner or fans
    Electrical Specification
    RH Display Yes
    Power Supply 12 Vdc @ 600 mA
    Auxiliary Power Supply 120 V – 60 Hz – 15 A (each iGS-25)
    Output Maximum Current 120 V, 15 A, 2 HP (1 circuit), 120 V, 30 A, 4 HP (2 circuits), 120 V, 45 A, 6 HP (3 circuits)
    Dry Contacts for Alarms N.O or N.C., fail safe or standard, 6 A @ 120 Vac ou 2A @ 30 Vdc
    AC Adapter Power Supply 12V DC center positive 800 mA min
    Splash Proof Membrane Front panel
    Operating Conditions 0 to 60 °C, 0 to 95 % non-condensing RH
    Manufacturer
    Warranty 3 years
    Technical Support Free support from 12 PM to 9 PM Monday to Friday, Eastern Time