iGS-111

Why use many climate controllers when a single one can perfectly manage temperature and relative humidity? No more need to coordinate many controllers together, the iGS-111 prioritizes actions according to a logical sequence and avoiding contradictory actions like heating and cooling at the same time. It intelligently and simultaneously manages 4 devices, giving you advices, detect equipment failures and manages alarms. Thanks to the integrated management of climate, the iGS-111 makes it easy to maintain a precise comfort zone for plants.

  • Description

    Control Module
    The controller intelligently manages 4 actions: heating, cooling (AC or fan), humidifying and dehumidifying. It allows adjustment of 5 set points per climate parameter: set points for day, night, temperature and humidity's differential, alarm and event logging. The controller database allowing you to know the real conditions of your garden over the last 24 hours.
    • Temperature precise sensor: ±1.8°F (±1°C)
    • Photocell to enable day/night set points
    • Relative humidity precise sensor: ±3.5% RH
    • Displays climatic conditions, advices, alarms and errors

    Connection module
    Connected to a compatible alarm system (0.6 A @ 120 Vac or 2A @ 30 Vdc), the connection module will activate alarms to notify a temperature or a humidity control problem. The two IGS-25 power boxes, each controlling your equipment with 2 auxiliary outputs, can be connected (Ethernet or RG45 cable) on different circuits up to 50 feet of the connection module.
    • Two IGS-25 power boxes (4 auxiliary outputs)
    • Dry contacts for temperature and/or humidity alarms


    Fresh Air Intake
    Without CO2 enrichment
    The continuous operation of fan(s) is recommended during the day or a CO2 controller (iGS-061) with a fan speed control (iGS-070) forms an effective combination to control ventilation providing available CO2. Plug a power strip in an auxiliary outlet of the temperature and humidity controller (iGS-110) and plug the temperature or humidity prioritized equipment and the iLS120-OFF sense cord. Feed the iLS120-OFF in different circuit and plug in a CO2 controller (iGS-061 or iGS-100) to manage CO2 enrichment equipment.
    With CO2 enrichment
    Fans may be operated a few minutes per hour Especially if you use combustion CO2 generator, the ventilation for at least 2 to 5 minutes is mandatory to replenish the oxygen supply required by the generator's combustion.

    Capacity
    The iGS-111 feeds up to 30 amps of controlled equipment (need two separate circuits 110-120 V). Equipment which uses other voltage then 110-120 V, like large capacity air conditioning unit, may be controlled by using an iGS-DCS. You can also increase the capacity with a load switcher box iLS4- 121, iLS4-121s or iLS4-241.
    • 120 V, 15 A, 2 HP load capacity (1 circuit)
    • 120 V, 30 A, 4 HP load capacity (2 circuits)

  • Specifications
    Controller Functions
    Integrated Controller Yes
    Digital Display Yes
    Info, Error or Alarm Messages Yes
    Day/Night Detection Photocell
    Day and Nigth Setpoints Yes
    Adjustable Operation Priority No
    Intelligent Self Management Equipment Yes
    Performance Analysis Temperature and RH Control
    Self Audit of Controller Errors Yes
    Data Log Last 24 hours
    Contact for External Alarms Temperature and RH
    Integrated Fan for Air Sampling Magnetic levitation sleeve bearing, 7 cfm
    Auxiliary Devices Control
    Controlled Actions Heating and Cooling and Humidifying and Dehumidifying
    Controlled Auxiliary Outputs 2 x iGS-25 (4 auxiliary outlets)
    Simultaneously Controlled Equipment 4 (2 for temperature and 2 for RH)
    Temperature Control
    Temperature Display Yes
    Temperature Sensor Accuracy ±1.8°F (±1°C)
    Temperature Sensor Range -4 °F to +122 (-20 °C to +50 °C)
    Adjustable Temperature Setpoint Yes
    Temperature Differential Fix
    Adjustable Temperature Differential Yes
    Controlled Equipment for Temperature Heater or Air Conditionner or Fans
    Humidity Control
    RH Display Yes
    RH Sensor accuracy ± 3,5 % RH
    RH Sensor Range 0 à 100 % HR
    Adjustable RH Setpoint Yes
    RH Differential Fix
    Adjustable RH Differential Yes
    Controlled Equipment for RH Humidifier and Dehumidifier
    Electrical Specification
    Power Supply 12 Vdc @ 600 mA
    Auxiliary Power Supply 120 V – 60 Hz – 15 A (each iGS-25)
    Output Maximum Current 120 V, 15 A, 2 HP (1 circuit), 120 V, 30 A, 4 HP (2 circuits)
    Dry Contacts for Alarms N.O or N.C., fail safe or standard, 6 A @ 120 Vac ou 2A @ 30 Vdc
    AC Adapter Power Supply 12V DC center positive 800 mA min
    Splash Proof Membrane Front panel
    Operating Conditions 0 to 60 °C, 0 to 95 % non-condensing RH
    Manufacturer
    Warranty 3 years
    Technical Support Free support from 12 PM to 9 PM Monday to Friday, Eastern Time
    Country of Origin Canada