iGS-012

The IGS-012 prevents your plants from being damaged by overheating or to slow their growth once temperatures reaches unacceptable level. It temporarily turns off the lights or the CO2 generators and lets the grow room cool down before bringing them back. Just set the shutdown temperature and the downtime desired before bringing the equipment back on.

  • Description

    Features
    The iGS-012 does not have a display and the set points are adjustable using smooth rotating knobs with continuous adjustment. The restart delay cools your lamps before restarting. It has a precise external temperature sensor on 20 inch cable (50 cm) to be placed at plants top level.
    • High temperature limit from 50 to 122°F (10 to 50°)
    • Temperature precise sensor: ±1.8°F (±1°C
    • Restart delay adjustable from 0 to 20 minutes

    Capacity
    The IGS-012 allows plugging up to 1400 w of equipment. You can also increase the capacity with one or many load switcher box such as iLS4-121, iLS4-121s or iLS4-241.

    • 120 V, 15 A, 2 HP load capacity

  • Specifications
    Controller Functions
    Digital display No
    Day and Nigth Setpoints Day only
    External probe 2'(50cm) cable
    Auxiliary Devices Control
    Controlled Actions Cooling
    Controlled Auxiliary Outputs 1 auxiliary outlet
    Simultaneously Controlled Equipment 1 (temperature control)
    Time control
    Adjustable Restart Delay from 0 to 20 min
    Temperature Control
    Temperature Sensor Accuracy ±1°F (±0,6°C)
    Adjustable Temperature Limit 70 to 120ºF (21 to 49ºC)
    Controlled Equipment for Temperature HID Lamps or CO² Burner
    Electrical Specification
    Power Supply 120 V – 60 Hz – 15 A
    Output Maximum Current 120 V, 15 A, 2 HP
    Operating Conditions 0 to 60 °C, 0 to 95 % non-condensing RH
    Manufacturer
    Warranty 3 years
    Technical Support Free support from 12 PM to 9 PM Monday to Friday, Eastern Time
    Country of Origin Canada